TEMPERATURE DISTRIBUTION MEASUREMENT IN AN AXIALLY SYMMETRIC SOURCE WHICH IS NOT OPTICALLY THIN

HRVOJE SKENDEROVIĆ, VLADIS VUJNOVIĆ NAZIF DEMOLI and JADRANKA RUKAVINA*
Institute of Physics of the University, Bijenička c. 46, Zagreb, Croatia
*Lamp factory, Zagreb

Received 3 October 1994

We elaborated two spectroscopic methods for the temperature distribution in axially symmetric source. One method uses the self-reversed spectral line; this method is based on a comparison of the measured absolute maximum (peak) intensity with that calculated as a function of axial temperature. Another method which uses a spectral line without self-reversal, was based on the Kirchhoff's law and exploits two-path absorption technique and Abel transformation. For both methods, knowledge of atomic broadening constants and transition probabilities is not crucial.

UDC 533.95
PACS 35.80.+s

 

 