FIZIKA B 10 (2001)  4, 247-254

 size 590 kBsize 703 kB

EXPERIMENTAL ARRANGEMENT FOR INVESTIGATION OF b+-DECAY END-POINT ENERGIES

ZVONKO KREČAK, MILICA KRČMAR, STANKO KAUČIĆ and ANTE LJUBIČIĆ

Ruđer Bošković Institute, POB 180, HR-10002 Zagreb, Croatia

Dedicated to Professor Kseno Ilakovac on the occasion of his 70th birthday

Received 5 September 2001; revised manuscript received 21 January 2002
Accepted 21 January 2002        Online 6 April 2002

We describe an experimental arrangement for the investigation of b+-decay end-point energies based on the use of a surface barrier silicon detector for b-particles and two Ge(HP) detectors for photons in a three-axes detection geometry. The system was tested using a 58Co source. The positron end-point energy determined by the Fermi plot analysis of the experimental data was found to be in good agreement with the values quoted in the literature.

PACS numbers: 23.40.-s, 06.60.Ei, 06.90.+v
UDC 539.1.078, 539.165,539.124.6

Keywords: b+-decay end-point energy, three-axes detection geometry, b-g coincidences

Copyright by The Croatian Physical Society